Zone 0 GuideIndependent. For California homeowners. Search Get alerts

Home / What insurers look for / The bottom 6 inches of the walls and flashing

Do I need flashing or noncombustible material on the bottom 6 inches of my walls?

Insurers ask for noncombustible material on the bottom 6 inches of every exterior wall. IBHS Essential requires it. It does not have to be flashing. It is not in the state draft.

The state Zone 0 rule is not law yet. Insurers and IBHS already use their own lists.

What to check

  1. Walk every outside wall. Look at the lowest 6 inches above the ground.

  2. Look again above any deck or patio that touches the wall.

  3. Note wood siding, trim or corners in that band.

  4. Check deck posts and stair bases too.

  5. Ask your insurer what it accepts before you spend money.

What each list says

The lists do not always agree. Here is what each one says about this.

IBHS Essential

At least 6 inches of noncombustible material applied vertically at the base of all exterior walls. It is measured from the ground up to the nearest horizontal surface, such as a deck or patio. Combustible deck posts need the same covering (sections 2.1.4 and 2.1.5).

State discount list

Noncombustible material 6 inches at the bottom of walls.

FAIR Plan

6 inches at the bottom of all exterior walls made of noncombustible material.

San Diego

A voluntary step: a minimum 6-inch metal flashing, applied vertically on the exterior of the wall where a deck meets it.

State draft

The August 2026 draft, as we read it, sets no standard for this.