Are the insurer lists stricter than the Board of Forestry's Zone 0 rule in the first 5 feet?
Updated October 18, 2026
Yes. IBHS Essential asks for a noncombustible zone: bare mineral soil and noncombustible ground cover. The FAIR Plan asks for the zone to be cleared. The Board of Forestry's Zone 0 rule would still let some low plants stay. If your goal is insurance, the stricter list is the safer target.
The Board of Forestry's Zone 0 rule is not in force yet. Insurers and IBHS already use their own requirements.

IBHS Essential and the FAIR Plan
Nothing that burns in the first 5 feet. Gravel, pavers or bare soil.

The Board of Forestry rule (proposed)
A bare strip along the walls. Past it, short lawn and small, low plants can stay.
What to check
Start with what both lists agree on: mulch, firewood, debris, shrubs and anything stored under decks.
Then look at what the Board of Forestry rule allows but IBHS does not: low plants and a short lawn. The FAIR Plan also asks for noncombustible fences and gates within 5 feet.
Ask your insurer which standard it uses.
Check each item on the is it allowed pages.
What each list says
The lists do not always agree. Here is what each one says about this.
- IBHS Essential
The zone runs 5 feet from the walls and from the outermost deck or overhead posts, up to the sky. It must be noncombustible. Vegetation, trees, limbs and vines in or over it come out, down to bare mineral soil. Wood and rubber mulch and exposed weed cloth come out. Gravel, pavers, decomposed granite and concrete are fine (section 2.2.1).
Combustible fences, gates and retaining walls in the zone are replaced. No vehicles. Most combustible items are removed, with a few listed exceptions. Movable items go indoors or 30 feet away during Red Flag Warnings or long absences.
- Safer from Wildfires
A 5-foot ember-resistant zone around the structure.
- FAIR Plan
Vegetation, debris, mulch and other combustible materials cleared within 5 feet. Only noncombustible materials in improvements within 5 feet, including fences and gates.
- State law now
Already required in the first 5 feet: roof clear of leaves and needles, no tree within 10 feet of a chimney, no dead wood over the house, no firewood (30 feet out unless fully covered), nothing stored under decks. Applies now to every building in a State Responsibility Area, in any fire hazard zone, and in Very High fire hazard zones in Local Responsibility Areas.
- Board of Forestry rule (proposed)
No bark mulch, firewood or debris that burns. Plant-free strips along the walls. Low, well-kept non-woody plants can stay elsewhere in the 5 feet. A combustible fence can stay if the last 5 feet at the house does not burn.
- Where the Board of Forestry rule allows more than IBHS, such as a short lawn or a low planting, an insurer that uses IBHS could still ask for it to go.
Sources
- IBHS Wildfire Prepared Home Technical Standard (2025 edition)
- Safer from Wildfires regulation: frequently asked questions, California Department of Insurance, September 2026
- Discounts for dwelling fire and commercial policies, California FAIR Plan, November 15, 2025
- Notice of proposed emergency action: Zone 0 defensible space, Board of Forestry, August 20, 2026
- Public Resources Code section 4291, via Justia
- 14 CCR 1299.03: defensible space requirements, Board of Forestry, via Justia Regulations
Related questions
- What do insurers want on and under my deck?
- Do I need flashing or noncombustible material on the bottom 6 inches of my walls?
- What is the IBHS Wildfire Prepared Home designation?