What size screen or mesh should go over vents?

Mesh with openings no bigger than 1/8 inch, or vents tested to the ASTM E2886 standard. The Safer from Wildfires and FAIR Plan lists both ask for ember-resistant vents. The Board of Forestry's Zone 0 rule sets no vent standard.

The Board of Forestry's Zone 0 rule is not in force yet. Insurers and IBHS already use their own requirements.

Close-up drawing of a louvered attic vent high in a gable wall. Embers blow at it and stop at the fine metal mesh behind the slats.

Attic (gable) vent

Close-up drawing of a short, wide crawl-space vent at the bottom of a wall, covered with fine metal mesh. Embers blow across the gravel and stay outside.

Crawl-space vent

Both have metal mesh with openings no bigger than 1/8 inch, as IBHS asks.

What to check

  1. List every opening: attic vents, crawl space vents, eave vents, dryer vent, skylights and chimney.

  2. Check what covers each one.

  3. Ask your insurer whether it wants tested vents or fine mesh.

  4. If you use tested vents, seal the joints as the maker instructs.

What each list says

The lists do not always agree. Here is what each one says about this.

IBHS Essential

Either corrosion-resistant vents that meet ASTM E2886, or noncombustible, corrosion-resistant mesh with openings no larger than 1/8 inch. If you use tested vents, joints around them are sealed as the maker instructs. Dryer and central vacuum vents get a working louver or flap instead of mesh (section 2.1.3).

IBHS Enhanced

The louvers or flaps on those vents must also be noncombustible. Operable skylights need noncombustible mesh with openings no larger than 1/8 inch (sections 3.1.3 and 3.1.5).

Safer from Wildfires

Ember- and fire-resistant vents.

FAIR Plan

Ember- and fire-resistant vents, with approved wire mesh covering.

San Diego

A voluntary step: mesh with 1/16 to 1/8 inch openings as a temporary option. Chimney and stovepipe outlets use mesh with 3/8 to 1/2 inch openings.

Board of Forestry rule (proposed)

Only about plants: none within 2 feet of windows, doors or vents. It sets no standard for vents or screens.